Product Index 
Call our Sales Team
01903 538 488    [email protected]
Mon - Fri 8am - 6pm
My Account
GBPLogin0 Items
Product Index 
Call our Sales Team
01903 538 488
Mon - Fri 8am - 6pm
My Account
GBPLogin0 Items
Call our Sales Team
01903 538 488
Mon - Fri 8am - 6pm
My Account
GBPLogin0 Items
01903 538 488
My Account
MENU

Seagull Post and Wire Kits For Surface Mounting


Seagull Post and Wire Kits For Surface MountingSeagull Post and Wire Kits For Surface MountingSeagull Post and Wire Kits For Surface Mounting
PW269 - 15m Seagull Post and Wire Kit For Surface Mounting
£83.26 Each inc. VAT
PW270 - 30m Seagull Post and Wire Kit For Surface Mounting
£103.68 Each inc. VAT
PW271 - 60m Seagull Post and Wire Kit For Surface Mounting
£145.32 Each inc. VAT
PW272 - 90m Seagull Post and Wire Kit For Surface Mounting
£192.11 Each inc. VAT

Each kit contains the following:

  15m Kit 30m Kit 60m Kit 90m Kit
Gull Wire 0.96mm 1 X 7 304 Stainless Nylon Coated 50m 100m 150m 200m
Gull Post 150mm Single Headed For Surface Mounting 12 22 42 62
Grey Surface Mount Base 16 26 46 66
Gull Wire Micro Spring 10 20 40 60
Gull Wire 1mm Copper Crimp 100 100 100 200
Silicone Adhesive 300ml 1 1 1 1
Surface Activator 1 1 1 1
Bird Wire Crimp Tool 1 1 1 1

This kit is intended for use on non-masonry substrates that can not take anchor rivets, including metal, plastic and glass. If you require post & wire to be used on masonry substrates then you should consider using our post and wire masonry kit or our range of specialist brackets for gutters, steel beams, pipes or rails.

This surface mount kit for seagull post and wire provides suffidcient materials for a run of 150mm single-head posts. Parallel rows should be set no more than 100mm apart (max 100mm behind first row).

Once the posts are seated in their surface mount bases the heads of the posts will be at 150mm.

Maximum distance between seagull wire posts = 3000mm (3m)

Seagull wire should be spring-tensioned every 3000mm (3m) along its run, i.e. the wire should stop at a spring on each post and start with a newly crimped section of the other side of the post.

In doing so you are spreading the load evenly across the post system and thus avoiding spring overload

Do not thread the pigeon wire through the eyelets of the post and onwards to the next post, as this will cause the system to sag and go out of shape.

The system should be counter-tensioned at the end of each run using the screw-pin and plugs provided. To avoid the system from sagging do not use springs in the counter-tension wires.

PestFix Post & Wire System Technical Specification

Bird Control
Rodent Control
Insect Control
Animal Control
Shooting Accessories and Consumables
Tools Cleaning and PPE
Training
Find a Pest Controller
Common Problem Areas
Trade Customers
Resource Centre
Customer Services
Contact Us
Special Offers